Description:

Maximum efficientiam, altam fidem, humilis sumptus

AC input range delecti switch

C% plenum onus ardeat in test

Praesidia: Brevis circuitu / Per onus / Per voltage

Refrigerium per liberum caeli convection

Certa commutatione frequentiae ad XXV KHz

II annis warantum


Product Detail

Product Tags

Features

145W Single Output Switching Power Supple S-145 series

Maximum efficientiam, altam fidem, humilis sumptus

AC input range delecti switch

C% plenum onus ardeat in test

Praesidia: Brevis circuitu / Per onus / Per voltage

Refrigerium per liberum caeli convection

Certa commutatione frequentiae ad XXV KHz

II annis warantum

Specifications

SPECIFICATIONS
REFERO  
Model S-145-5 S-145-7.5 S-145-12 S-145-15 S-145-24 S-145-32
DC Voltage 5V 7.5V 12V 15V 24V 32V
Ratum Current 25A 18A 12A 9.6A 6A 4.5A
Current dolor 0-25A 0-18A 0-12A 0-9.6A 0-6A 0-4.5A
Rated potestas 125W 135W 144W 144W 144W 144W
Ripple & Noise 100mVp-p 120mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p
intentione Adj.Range ±10% -20%; + X% -12%; + X% -12%; + X% -12%; + XVI% -12%; + XVI%
Tolerantia intentione ±2% ±1% ±1% ±1% ±1% ±1%
Setup, surge, sustine Tempus 100ms, 50ms, 20ms ad onus plenum
INPUT  
Voltage Range 85~ 132VAC/ 180~ 264VAC delectum transibit 47~63Hz;255~ 370VDC
AC Current 3.2A/115V 1.6A/230V
Efficientia 78% 80.50% 80.50% 81% 83.50% 83.50%
INCURSUS Current Frigus committitur 35A/230VAC
ultrices Current <3.5mA/240VAC
PRAESIDIUM  
Plus Load 135%~165%
Tutela type: Occlude o/p intentione, re-virtus ad recuperandum
Plus intentione 115%~ 135%
Tutela type: Occlude o/p intentione, re-virtus ad recuperandum
ENVIRONMENT  
Opus Temp., Umor -10℃~+60℃;20%~90% RH
Repono Temp., Umor -20℃~+85℃;10%~95% RH
Vibratio 10~ 500Hz, 2G 10min./1cyclus, periodus 60minorum, singuli per axes X, Y, Z.
SALUS  
sustinere intentione I/PO/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC
Repugnantia solitudo I/PO/P, I/P-FG, O/P-FG:100M Ohms/500VDC
VEXILLUM  
Salus Standard Design refer to UL1012
EMC Standard Design refer to EN55022, IEC801-2, 3,4
ALIIS'  
Dimension 199*98*38mm(L*W*H)
Pondus 0.71Kg
stipare 30pcs/22.5kg/1.22CUFT
NOTA  
1. Omnes parametri NON nominatim metiuntur 230VAC initus, onus aestimatus et 25℃ temperatus ambientis.
2. Ripple & sonitus mensurae sunt ad 20MHz band longitudinis utendo 12" filum coniugationis contortum cum 0.1μ & 47μ capacitatis parallelis terminatum.
3.Tolerance: tolerantiae inclusae erectae, rectae regulae et onus regulae

 