·Input et output separatim sunt
·THD<3%
· DUXERIT Indicatores ostendit opus et defectum status
· Praesidia: onerare, super intentione, input verticitatem e converso, ambitum brevem etc
· Total 100% clean waveform output 12v pure sine fluctus inverter
· refrigeratum ab intus DC ventilabrum
·Conterere potes 12V 800W undam puram sine invertitur ad eam tuendam
Model | OPIP-0800-1 | OPIP-0800-1 | OPIP-0800-1 | OPIP-0800-2 | OPIP-0800-2 | OPIP-0800-2 |
Rated potestas | 800W | |||||
Apicem potentia | 1600W | |||||
Input voltage | DC12V | DC24V | DC48V | DC12V | DC24V | DC48V |
Output voltage | 100VAC vel 110VAC vel 120VAC±5% | 220VAC vel 230VAC vel 240VAC .±5% | ||||
Exonerare current minus, quam | 0.8A | 0.5A | 0.3A | 0.8A | 0.5A | 0.3A |
Output frequency | 50Hz±0.5Hz vel 60Hz±0.5Hz | |||||
output waveform | Purus Sine Wave | |||||
Waveform distortio | THDIII% (linearibus onus) | |||||
USB portum | 5V 1A | |||||
Max.efficiency' | 90% | |||||
Input voltage range | 10-15.5V | 20-31V | 40-61V | 10-15.5V | 20-31V | 40-61V |
Humilis voltage terrorem | 10.5±0.5V | 21±0.5V | 42±1V | 10.5±0.5V | 21±0.5V | 42±1V |
Humilis voltage praesidium | 10±0.5V | 20±0.5V | 40±15V | 10±0.5V | 20±0.5V | 40±15V |
Per voltage praesidium | 15.5±0.5V | 31±0.5V | 61±1V | 15.5±0.5V | 31±0.5V | 61±1V |
Humilis voltage recuperet | 13±0.5V | 24±0.5V | 48±1V | 13±0.5V | 24±0.5V | 48±1V |
Per voltage recuperet | 14.8V±0.5V | 29.5V±0.5V | 59V±1V | 14.8V±0.5V | 29.5V±0.5V | 59V±1V |
Munus tutelae | Humilis voltage | Terror primo, intentione continenter minuendo.DUXERIT RED lucem, & clausa seminat. | ||||
Per voltage | DUXERIT rubrum lux clausa descendit | |||||
Per onus | DUXERIT rubrum lux clausa descendit | |||||
Plus temperatus | Terrorem primo, tempuratura continenter rise.LED lucem rubrae in&sementis inclusi | |||||
Brevis circuitus | DUXERIT rubrum lux on | |||||
Input contra verticitatem | Fuse ardeat | |||||
opus temperatus | -10°- +50° | |||||
Repono temperatus | -30°- +70° | |||||
Dimensio (mm) | 296x180x78mm | |||||
Sarcina (mm) | 360x335x100mm | |||||
Net./gross weight(g) | 2760/3230g | |||||
QTY/Ctn | 8 Pcs | |||||
Meas./Ctn(mm) | 500x400x415mm | |||||
Crassa pondus / Ctn(g) | 25840g | |||||
Warranty | 1.5 annis | |||||
Configurationis | Standard | |||||
Modus refrigerandi | Intelligentes aeris refrigerationem | |||||
Nota: fructus nostros constanter renovant. The parameter technicus est ad referendum solum. Quaeso refer ad nostrum verum opus. |
1, de intentione DC constare debet
Quilibet invertor accessus ad valores DC voltage, ut 12V, 24V, etc., requiritur ad eligendum machinam intentionis consentaneam esse cum DC initus intentionis inverter. Exempli gratia, 12V invertor debet eligere 12V altilium.
2. Virtus inversi outputa maior esse debet quam vis adjumentorum electricorum, praesertim ad adjumenta electrica cum magna potestate ineunte, sicut leo et conditioners aer, sed etiam marginem magnam relinquent.
3. Positiva et negativa electrodes recte coniungi debent
Pars DC intentione cui inverter iungitur, positivis et negativis poles.Red positivus (+), niger negativus est (-), pugna etiam positivis et negativis notatur, rubra est positiva (+), nigra est. Negativa (-), nexus cum positivo (rubri), negativo (nigra). Connexio filum diametri satis crassum esse debet et longitudo filum connectens minimizari debet.
4, in ventilatis, siccis, pluviis cave, et cum objectis circumjacentibus plus 500px habent distantiam, a productis flammabilibus et explosivis, ne in machina vel alias res, usum temperatura environmental maior quam 40℃ non est.