LEYU specialitas in inverters producendis et vendendis UPS.Nostra bona religio facit clientes nostros bonam experientiam frui, cum utuntur pura potestate nostra UPS inverto 2000W.Bonam famam e clientibus terrarum accipimus.Salvete omnes amici ex toto orbe ut nos quaerentes mittat.Responsum intra 24 horas (praeter ferias).
Translatio Nullam ultra ieiunium
Humilis impedimento technologiae
Universale praesidium circuit
Turbo refrigerationem
Princeps Efficens
Lorem III scaena internus altilium patina
UPS munus
THD infra III%
50HZ vel 60HZ output
10A vel 15A altilium patina
Model | OPIP-2K-1 | OPIP-2K-1 | OPIP-2K-1 | OPIP-2K-2 | OPIP-2K-2 | OPIP-2K-2 |
Rated potestas | 2000W | |||||
Apicem potentia | 4000W | |||||
Altilium patina | 20A | 20A | 20A | 20A | 20A | 20A |
Input voltage | DC12V | DC24V | DC48V | DC12V | DC24V | DC48V |
Output voltage | 100VAC vel 110VAC vel 120VAC±5% | 220VAC vel 230VAC vel 240VAC±5% | ||||
Exonerare current minus, quam | 1.1A | 0.7A | 0.5A | 1.1A | 0.7A | 0.5A |
Output frequency | 50Hz±0.5Hz vel 60Hz±0.5Hz | |||||
output waveform | Purus Sine Wave | |||||
Waveform distortio | THD <III% (linearibus onus) | |||||
USB portum | 5V 1A | |||||
Max.efficiency' | 90% | |||||
Input voltage range | 10-15.5V | 20-31V | 40-61V | 10-15.5V | 20-31V | 40-61V |
Humilis voltage terrorem | 10.5±0.5V | 21±0.5V | 42±1V | 10.5±0.5V | 21±0.5V | 42±1V |
Humilis voltage praesidium | 10±0.5V | 20±0.5V | 40±15V | 10±0.5V | 20±0.5V | 40±15V |
Per voltage praesidium | 15.5±0.5V | 31±0.5V | 61±1V | 15.5±0.5V | 31±0.5V | 61±1V |
Humilis voltage recuperet | 13±0.5V | 24±0.5V | 48±1V | 13±0.5V | 24±0.5V | 48±1V |
Per voltage recuperet | 14.8V±0.5V | 29.5V±0.5V | 59V±1V | 14.8V±0.5V | 29.5V±0.5V | 59V±1V |
Munus tutelae | Humilis voltage | Terror primo, intentione continenter minuendo.DUXERIT RED lucem, & clausa seminat. | ||||
Per voltage | DUXERIT rubrum lux clausa descendit | |||||
Per onus | DUXERIT rubrum lux clausa descendit | |||||
Plus temperatus | Terrorem primo, tempuratura continenter rise.LED lucem rubrae in&sementis inclusi | |||||
Brevis circuitus | DUXERIT rubrum lux on | |||||
Input contra verticitatem | Fuse ardeat | |||||
opus temperatus | -10°- +50° | |||||
Repono temperatus | -30°- +70° | |||||
Dimensio (mm) | 397x180x78mm | |||||
Sarcina (mm) | 500x240x150mm | |||||
Net./gross weight(g) | 4100/4500g | |||||
QTY/Ctn | 4 Pcs | |||||
Meas./Ctn(mm) | 510x490x315mm | |||||
Crassa pondus / Ctn(g) | 18200g | |||||
Warranty | I annis | |||||
Configurationis | Standard | |||||
Modus refrigerandi | Intelligentes aeris refrigerationem |
1. Quid est supra intentionem tutelam UPS invertendi?
Super voltage protection of 12V generis est 15.5±0.5V, 24V genus est 31±0.5V.
2. Quo circa partus tempus?
7 diebus ad specimen;25 dies pro mole ordinis.
3. Quomodo solvere problema technicum?
Tibi liberum technicum praestabimus, si quaestio cum UPS invertitur.
4. Ubi sita est officina tua?Quomodo ibi visitabo?
In urbe Yueqing sita sumus, huc venire potes velo cursu vel plano ad Wenzhou aeroportus.
5. Potestne vilius esse pretium?
Utique, pro magna quantitate bona offeretur.
6. Potuistine imprimere nostram societatem logo in nomine ac sarcina?
Etiam ordines OEM suscipimus.Logom tuum in UPS invertere possumus imprimere.